Innovation Delivered

Get to talk about preclinical in vivo imaging related topics, trends, events and more.
Jun
23

a methodology study in scientific reports

Effects of administration route on uptake kinetics of 18F‑sodium fluoride positron emission tomography in mice

 Zaniah N. Gonzalez‑Galofre1,2, Carlos J. Alcaide‑Corral1,2 & Adriana A. S. Tavares1,2

1British Heart Foundation/University of Edinburgh Centre for Cardiovascular Science

2Edinburgh Imaging, University of Edinburgh, Little France Campus, Edinburgh

3British Heart Foundation/University of Edinburgh Centre for Cardiovascular Science

 https://doi.org/10.1038/s41598-021-85073-0

Summary

18F-sodium fluoride (18F-NaF) is a positron emission tomography (PET) radiotracer widely used in skeletal imaging and has also been proposed as a biomarker of active calcification in atherosclerosis. Like most PET radiotracers, 18F-NaF is typically administered intravenously. 

However, in small animal research intravenous administrations can be challenging, because partial paravenous injection is common due to the small calibre of the superficial tail veins and repeat administrations via tail veins can lead to tissue injury therefore limiting the total number of longitudinal scanning points. In this paper, the feasibility of using intra-peritoneal route of injection of 18F-NaF to study calcification in mice was studied by looking at the kinetic and uptake profiles of normal soft tissues and bones versus intravascular injections.

In soft tissue, the 18F-NaF perfusion phase changes depending on the type on injection route, whereas the uptake phase is similar regardless of the administration route. In bone tissue standardised uptake value (SUV), standardised uptake value ratio (SUVr) and uptake constant (Ki) measures were not significantly different between the three administration routes.

 Authors have concluded that, intra-peritoneal injection is a valid and practical alternative to the intra-vascular injections in small-animal 18F-NaF PET imaging and provides equivalent pharmacokinetic data. Furthermore, their data show that CT outcomes report on sites of stablished calcification whereas PET measures sites of higher complexity and active calcification.

 

Results from nanoScan PET/CT

Mice received an intra-vascular or intra-peritoneal injection of 18F-NaF as follows: intra-arterial administration (8.68 ± 3.94 MBq, mean ± SD, n = 7) via femoral artery; intra-venous administration via femoral vein (7.43 ± 4.69 MBq, mean ± SD, n = 6); and intra-peritoneal administration (7.85 ± 2.18 MBq, mean ± SD, n = 6). Immediately post-radiotracer administration, a 60 min whole-body emission scan was obtained. PET data was reconstructed into 6 × 30 s, 3 × 60 s, 2 × 120 s, 10 × 300 s frames using Mediso’s iterative Tera-Tomo 3D reconstruction algorithm and the following settings: 4 iterations, 6 subsets, full detector model, low regularisation, spike filter on, voxel size 0.4 mm and 400–600 keV energy window.

Figure 1.  Representative examples of biodistribution of 18F-sodium fluoride (NaF) after femoral artery, femoral vein and intra peritoneal injections presented as average sagittal section images between 45 and 60 min post-injection (A). Mean time-activity curves of the vena cava (B), heart (C), lungs (D), liver (E) and kidneys (F) after femoral, artery, femoral vein or intraperitoneal (IP) injection. Error bars represent one SEM. SUV standardised uptake value.

Continue reading
  154 Hits
0 Comments
154 Hits
  0 Comments
Apr
21

On Parkinson's Disease Awareness Month, we would like to post a publication from Korea Research Institute of Bioscience and Biotechnology (KRIBB)

A non-human primate model for stable chronic Parkinson’s disease induced by MPTP administration based on individual behavioral quantification

https://doi.org/10.1016/j.jneumeth.2018.10.037

Summary

Parkinson’s disease (PD) is a neurodegenerative disease that affects about 3% of the population over 65 years of age. PD is characterized by a selective loss of dopaminergic neurons accompanied by movement disorders, including rigidity, bradykinesia, akinesia, tremors, and postural instability.

The authors aimed to develop a MPTP-induced chronic NHP model with stable symptoms by adjusting MPTP treatment based on individual behavioral quantification using a video-based analysis system. To validate this strategy, they assessed a parkinsonian behavior score, an immunohistochemistry Western blot, and PET imaging of dopamine transporter (DAT) with [18F] N-(3-fluoropropyl)-2ß-carboxymethoxy-3β-(4-iodophenyl) nortropane (18F-FP-CIT).

The authors stated that the novel strategy of MPTP administration based on global activity evaluations using a video-based analysis system provides an important conceptual advance of this method for the development of chronic NHP PD models.

Results from nanoScan PET/CT

Mediso’s nanoScan PET/CT with 16cm bore size, 12 cm transaxial and 10 cm axial Field of View (FOV) were suitable to execute PET/CT scans in cynomolgus monkeys (Macaca fascicularis). Furthermore high spatial and temporal resolution of PET allowed to determine the dopamine transporter biding potential (BP) in different striatal sub-regions.

Following a CT scan for attenuation correction, 185 MBq 18 F-FP-CIT in 1.5 ml saline was injected intravenously via the saphenous vein. To monitor presynaptic dopamine transporter activity in vivo, serial 18F-FP-CIT PET imaging was performed after MPTP administration.

  • The biding potential analysis revealed that the 18F-FP-CIT BP were significantly reduced in all sub-regions of the striatum at 8, 16, 24, 32,40 and 48 weeks following the first MPTP administration (Fig. 4A and 4B).
  • Monkeys with fewer striatal DAT tended to have lower global activity (GA), indicating that a decrease in GA reflects damage in dopaminergic neurons.
  • The severity of Parkinsonian symptoms and the loss rates of DAT in each striatal sub-region did not correlate with the total dose of MPTP, indicating that a fixed MPTP dose is not a good strategy for development of chronic NHP PD models

Fig. 4. (A) Representative 18F-FP-CIT PET images fused with individual MRI. (B) Histogram representing 18F-FP-CIT binding potential (BP) in the MPTP-injection group. (#P < 0.05, *P<0.01 vs. baseline). (C) Histogram representing time activity curve. The radiotracer uptake in each region of interest was estimated as the standardized uptake value (SUV), which was calculated as decay-corrected activity per milliliter of tissue volume per injected radiotracer activity per body mass ([kBq/mL]/[kBq/g]). Ant, anterior; binding potential, BP; Ext, external; pallidum, globus pallidus; Int, internal; Post, posterior.

Continue reading
  162 Hits
0 Comments
162 Hits
  0 Comments
Apr
06

High-throughput PET/CT under testing: oncology and neurology studies using the Mediso Mouse Hotel:

Validation of Image Qualities of a Novel Four-Mice Bed PET System as an Oncological and Neurological Analysis Tool

Kyung Jun Kang1Se Jong Oh1Kyung Rok Nam1Heesu Ahn1,2Ji-Ae Park1,2Kyo Chul Lee1, Jae Yong Choi1,2
1Division of Applied RI, Korea Institute of Radiological and Medical Sciences, Seoul 01812, Korea
2Radiological and Medico-Oncological Sciences, University of science and technology (UST), Seoul 01812, Korea

https://doi.org/10.3390/jimaging7030043

Summary
Molecular imaging is used for the diagnosis of oncological, neurological, and cardiovascular diseases. Positron emission tomography (PET) is a molecular imaging technique that enables quantitative measurements of biochemical parameters, such as metabolic changes and concentrations of neurotransmitters. The demand for preclinical research is increasing worldwide, as it can predict clinical trials and advance our understanding of the pathophysiological mechanisms underlying a specific disease. 
For this purpose, researchers use micro-PET (µPET), which is a small-animal dedicated system. Most µPET vendors provide a single bed, thereby allowing imaging of only a single animal at a time. Large-scale research involving many objects thus requires tremendous time and use of radioactivity.
Recently, Mediso developed a multi-bed system dedicated to the nanoScan scanners with the contribution of Tim Witney and his team at UCL and KCL, where the initial validity for research has been investigated. Greenwood et al. (https://doi.org/10.2967/jnumed.119.228692) tested the four-bed mouse system using 2-deoxy-2-(18F)fluoro-D-glucose (18F-FDG) in phantom and normal mice and reported a quantitative accuracy similar to that of a single-bed. To date, however, few studies have focused on the validity of oncological and neurological PET imaging of the four-mice bed system.
This study aimed to evaluate the image qualities of oncological and neurological PET imaging using a novel four-mice bed system.

Results from the nanoScan PET/CT
For the small animal imaging, the authors have used a nanoScan PET/CT, to see the differences using the single-bed vs. multi-bed scans regarding the image quality in oncological and neurological studies. The scanner has a peak absolute system sensitivity of >9% in the 400–600 keV energy window, an axial field of view of 28 cm, a transaxial field of view of 35–120 mm, and a transaxial intrinsic resolution of 0.7 mm at 1 cm off-center.
For the phantom studies, following the guidelines of NEMA NU-4 2008, four phantoms were filled with 3.7 MBq of 18F-FDG in 10 mL of saline and decay-corrected to the start of acquisition. On the first day, four phantoms were imaged in the multi-bed system, and one day later a single phantom was imaged using a single-bed system for comparison. Static PET acquisition was performed using the nanoScan PET/CT over 20 min, followed by CT (480 projections; 50 kVp tube voltage; 630 µA; 300 ms exposure time; 1:4 binning). Whole-body TeraTomo 3D reconstruction with four iterations and six subsets was performed (1–5 coincidence mode) using an isotropic voxel size of 0.4 mm3.
In all the preclinical experiments, four animals were scanned in the multi-bed system, and then, single PET images were acquired using the single-bed system 2 days later. For the oncological study, prior to imaging, all mice fasted overnight. The mice were anesthetized with 2.5% isoflurane in oxygen, and 18F-FDG (8.8 ± 0.9 MBq/200 µL) was administrated into the tail vein. Based on previous studies, 18F-FDG images were acquired after 40–60 min. For the brain study, an 18F-FPEB PET tracer (8.7 ± 0.7 MBq/200 µL) was prepared. 18F-FPEB PET images were acquired 30–50 min after injection because the radiotracer initially shows specific-to-nonspecific binding values that reach a plateau after 30 min.  Images were reconstructed using TeraTomo 3D algorithm with four iterations. For attenuation correction, CT imaging was performed immediately after PET using 50 kVp of X-ray voltage with 0.16 mAs.
Figure 3. shows the main results from the oncological study, with representative PET/CT images of tumor-bearing mice after 18F-FDG injection in single- and multi-bed systems (A). The plane was chosen to best reflect the tracer uptake characteristics of each group. Comparison of tumor uptake values in single- and multi-bed systems based on tumor size (B,C), **** p < 0.0001, n.s.= statistically nonsignificant. PET/CT, positron emission tomography/computed tomography; SUVmax, maximum standardized uptake value.

Figure 4. shows the results from the neurological study. Summed 18F-FPEB brain PET images of the single-bed (n = 12) and each bed of the multi-bed system (A, n = 3 in each bed). Comparison of regional SUV values of single- and multi-bed systems (B,C). STR, striatum; HIP, hippocampus; SUV, standardized uptake value.

  • PET images acquired with the multi-bed system showed a lower estimation of radiation uptake compared to that of the single-bed system when images were acquired for small lesions. However, phantom studies showed that there were no differences between the single- and multi-bed systems for volumes > 4 mm and that multi-bed systems can be applied in oncological and neurological studies.
  • The multi-bed system may improve the efficacy of preclinical research by saving the time taken to acquire PET images.

Continue reading
  238 Hits
0 Comments
238 Hits
  0 Comments
Dec
08

In our new blogpost, the authors suggest a background mechanism for the nonaddictive opioid medication methadone, which is widely used as a treatment for opioid use disorder.

Opioid–galanin receptor heteromers mediate the dopaminergic effects of opioids

Ning-Sheng Cai1, César Quiroz1, Jordi Bonaventura2, Alessandro Bonifazi3, Thomas O. Cole4, Julia Purks5, Amy S. Billing6, Ebonie Massey6, Michael Wagner6, Eric D. Wish6, Xavier Guitart1, William Rea1, Sherry Lam2, Estefanía Moreno7, Verònica Casadó-Anguera7, Aaron D. Greenblatt4, Arthur E. Jacobson8, Kenner C. Rice8, Vicent Casadó7, Amy H. Newman3, John W. Winkelman5, Michael Michaelides2, Eric Weintraub4, Nora D. Volkow9, Annabelle M. Belcher4, Sergi Ferré1
1Integrative Neurobiology Section.
2Biobehavioral Imaging and Molecular Neuropsychopharmacology Unit and.
3Medicinal Chemistry Section, National Institute on Drug Abuse (NIDA), Intramural Research Program (IRP), NIH, Baltimore, Maryland, USA.
4Division of Alcohol and Drug Abuse, Department of Psychiatry, School of Medicine, University of Maryland, Baltimore, Maryland, USA.
5Massachusetts General Hospital, Departments of Psychiatry and Neurology, Harvard Medical School, Boston, Massachusetts, USA.
6Center for Substance Abuse Research, University of Maryland, College Park, Maryland, USA.
7Department of Biochemistry and Molecular Biomedicine, University of Barcelona, Barcelona, Spain.
8Drug Design and Synthesis Section, NIDA, IRP, and.
9NIDA, NIH, Baltimore, Maryland, USA.

https://doi.org/10.1172/jci126912

Summary
Identifying nonaddictive opioid medications is a high priority in medical science, but μ-opioid receptors (MORs) mediate both the analgesic and addictive effects of opioids. And as possibly everyone knows, the opioid epidemic shows a severe public health crisis worldwide.
Maintenance treatment with the (MOR) agonist methadone is the most highly researched and evidence-based treatment for opioid use disorder. Yet public perception concerning the substitution of illicit drugs (such as heroin) with medication (such as methadone) has led to stigmatized views of maintenance treatment, stalling the advancement of addiction treatment policy and access to medication-based treatments. MOR agonism also offers the most effective treatment for severe pain, making the search for a nonaddictive opioid drug the holy grail of pain research.
The neuropeptide galanin acts as a modulator of neurotransmission in the CNS and the PNS, and It is coexpressed with different neurotransmitters and coreleased by the major ascending noradrenergic, serotoninergic, histaminergic, and cholinergic systems. The authors recently reported the existence of functionally significant heteromers of the MOR and galanin 1 receptor (Gal1R) in the ventral tegmental area that could explain these galanin-opioid antagonistic interactions.
The present study sought to answer 2 main questions that arose from our study of MOR-Gal1R heteromers: (a) What are the mechanisms involved in the interactions between galanin and opioid ligands within the MOR-Gal1R heteromer? and (b) Do these interactions also involve morphine and synthetic opioids, such as methadone or fentanyl, differentially?

Results from nanoScan PET/CT
For the animal experiments, the authors have used a nanoScan PET/CT, which provided high resolution and sensitivity to follow the [18F]FDG uptake in the selected brain regions, and find significant differences after using the below mentioned drugs in rats.
The timeline of the experiment was slightly different from the usual PET/CT scans, as it involved two acquisitions: for the baseline scan, saline was injected i.p. (1 ml/kg) into the rats, and after 30 mins, [18F]FDG tracer was applied (i.p. as well). After 30 mins post-injection time, conventional 20 mins long PET/CT acquisitions was performed. After 2 days, the second part was coming, but instead of saline, morphine (1 mg/kg) or methadone (1 mg/kg) was injected i.p. After accessing [18F]FDG, the second PET/CT was conducted as before. For the reconstruction, Teratomo 3D engine was used with attenuation and scatter corrections, with a 0.4 mm resolution.

Figure 4. shows the main results from the PET/CT acquisitions: A. The timeline of the experiment (explained above). B. [18F]FDG uptake after administration of saline (baseline, n = 14), morphine (1 mg/kg, n = 7), or methadone (1 mg/kg, n = 7). Coronal and sagittal images (1.5 mm anterior to bregma and 1.4 mm lateral from the midline, respectively) show the average SUVR calculated using the whole brain as a reference region. C. Voxel-based parametric mapping analyses revealed significantly decreased metabolic activity from baseline values in a basal forebrain region that included the nucleus accumbens and its projecting areas after morphine, but not methadone, treatment. Statistical parametric maps of significant decreases of [18F]FDG uptake (P < 0.05, paired t test). D. and E. VOI analyses of the frontal cortex (FCx), dorsal striatum (DS), and basal forebrain (BF) region, showing a significant differential pattern of [18F]FDG uptake after administration of morphine (D) or methadone (E).

  • The authors found significant pharmacodynamic difference between morphine and methadone that is determined entirely by heteromerization of MORs with Gal1Rs, rendering a profound decrease in the potency of methadone. This finding was explained by the weaker proficiency of methadone in activating the dopaminergic system as compared with morphine and predicted a dissociation of the therapeutic and euphoric effects of methadone, which was corroborated by a significantly lower incidence of self-reports of feeling “high” in methadone-medicated patients.
  • These results suggest that μ-opioid–Gal1R heteromers mediate the dopaminergic effects of opioids. The results further suggest a lower addictive liability of some opioids, such as methadone, due to their selective low potency for the μ-opioid–Gal1R heteromer.

 

 

Continue reading
  425 Hits
0 Comments
425 Hits
  0 Comments
Dec
02

C-11 tracer studies using nanoScan PET/MRI and PET/CT in Vrije University Medical Center

PET imaging of P2X7R in the experimental autoimmune encephalomyelitis model of multiple sclerosis using [11C]SMW139

https://doi.org/10.1186/s12974-020-01962-7

 Summary

Neuroinflammation plays a central role in a variety of pathologies affecting the central nervous system (CNS), such as multiple sclerosis (MS), Alzheimer’s and Parkinson’s disease. Microglia are major contributor in disease’s pathogenesis, although the exact role of microglia and their activation status during the disease process is not understood exactly.

In this article the process of neuroinflammation has been studied in Lewis rats with experimental autoimmune encephalomyelitis (EAE), an animal model for MS.

Mediso nanoScan PET/CT and nanoScan PET/MRI were used for non-invasive imaging of the activation status of microglia and the ability to identify a pro- or anti-inflammatory environment.

The authors have used a C-11 isotope labelled purinergic receptor (P2X7R) ligand ([11C]SMW139) for tracing microglial activity. They assessed the tracer’s potential for imaging neuroinflammation and its specific binding to P2X7R. They also matched the molecular imaging result with autoradiography and immunohistochemistry.

The authors have shown that [11C]SMW139 is a promising PET tracer for imaging neuroinflammation and evaluating the dynamics of pro-inflammatory microglia in the brain.

 

Selected results from nanoScan PET/MRI and nanoScan PET/CT

  • They evaluated the uptake of [11C]SMW139 at the peak of inflammation and compared it to the uptake in the recovery phase.

Fig 1. Sagittal PET images extracted from the static reconstruction of the 5–45 min frame and showing [11C]SMW139 uptake in the brain and spinal cord (arrows) of severe-relapsing (a), severe acute (b). Arrow heads are showing [11C]SMW139 uptake in a brain draining lymph node

Fig 2. Sagittal PET images extracted from the static reconstruction of the 5–45 min frame and showing [11C]SMW139 uptake in the brain and spinal cord (arrows) of relapsing EAE rat (peak of the disease (e), relapse (f), recovery (g)) and non-relapsing rat ( of the disease (h), no-relapse (i), recovery (j)). S.C. spinal cord, CB cerebellum, B.S. brain stem. Data are expressed as percent injected dose per milliliter (%ID/mL)

  • They validated the specificity of [11C]SMW139 tracer binding to the EAE tissue

 

Fig 3. Correlation between uptake of [11C]SMW139 tracer in the brain of the EAE animal and the ex vivo immunostaining for IBA-1 and ED-1; Transversal (A) and sagittal (D) PET image section showing the uptake of the [11C]SMW139 in the brain. The dotted purple circles or rectangles mark the area with the highest uptake. The green and red spots in the brain indicate a high accumulation of [11C]SMW139; Immunostaining with IBA-1 (B, E) and CD68 (C, F) of the respective brain region post PET imaging showing high microglia activation in the same region where the high uptake of [11C]SMW139 was observed by PET imaging.

 

Continue reading
  323 Hits
0 Comments
323 Hits
  0 Comments
Sep
28

Observing the Word Alzheimer's Month - current research on nanoScan PET/CT

Electroacupuncture attenuates cognition impairment via anti-neuroinflammation in an Alzheimer’s disease animal model

Mudan Cai1, Jun-Hwan Lee2 and Eun Jin Yang2

1Department of Herbal Medicine Research, Korea Institute of Oriental Medicine, 1672 Yuseong-daero, Yuseong-gu, Daejeon, 305-811, Republic of Korea

2Department of Clinical Research, Korea Institute of Oriental Medicine, 1672 Yuseong-daero, Yuseong-gu, Daejeon, 305-811, Republic of Korea

https://doi.org/10.1186/s12974-019-1665-3

Summary

Current study investigated the electroacupuncture (EA)-induced molecular mechanisms causing cognitive improvement and anti-inflammatory activity in 5XFAD mice, a transgenic animal model of Alzheimer’s Disease (AD). Mice were bilaterally treated with EA three times per week for 2 weeks, thereafter Y-maze tests, western blots, immunohistochemistry, and PET scans were performed. Results revealed that EA treatment significantly improved working memory and synaptic plasticity, activated cell metabolism in the frontal cortex and the hypothalamus, concomitantly reduced neuroinflammation, ultrastructural degradation of synapses, and the microglia-mediated amyloid β deposition.

 

Results from nanoScan PET/CT

For the PET/CT studies, 7.4MBq 18F-FDG was intravenously injected via the tail vein to the following treatment groups: a) non-transgenic (non-Tg), b) 5XFAD (Tg) and c) EA-treated 5XFAD (Tg+KI3). After 60min uptake period, 30min long PET acquisitions were performed. Data were reconstructed with Tera-Tomo 3D reconstruction method. For quantitative analysis regions of interest were drawn into the frontal cortex, cortex, hippocampus, and hypothalamus and standardized uptake values (SUV) were evaluated to determine the effect of EA treatment on brain metabolism. Result revealed that:

  • EA stimulation caused a 1.1-fold increase in the mean glucose level of the frontal cortex, which is related to short-term and working memory showing that it improves cognitive functions

  • The hypothalamus, which is related to energy metabolism, exhibited a 1.1-fold decreased glucose metabolism in Tg mice compared to non-Tg mice, and this effect was fully reversed in EA-treated Tg mice proving that it modulates the abnormal hypothalamic metabolism related to the amyloid pathology in AD mice

 

 

Continue reading
  449 Hits
0 Comments
449 Hits
  0 Comments
Nov
10

Personalised cellular therapies will benefit from a sensitive PET cell tracking agent

Personalised cellular therapies will benefit from a sensitive PET cell tracking agent

Introduction

This post summarizes the results on a research of a new Zr89 PET tracer for cell labeling. The open access article was published last month in the European Journal of Nuclear Medicine and Molecular Imaging journal:

Charoenphun, P. et al. [89Zr]Oxinate4 for long-term in vivo cell tracking by positron emission tomographyEJNMMI (2014)

The preclinical PET/CT images were acquired on a nanoScan PET/CT in vivo small animal imaging system at King’s College London.

Increasing sensitivity of cell tracking by changing labeling and detection from SPECT to PET

Cell tracking by gamma imaging with radionuclides has been performed clinically for over 30 years and is used for tracking autologous leukocytes to detect sites of infection/inflammation. The standard radiolabelling methodology has been non-specific assimilation of lipophilic, metastable complexes of indium-111 (with oxine) or technetium-99m (with HMPAO). Regenerative medicine and immune cell-based therapies are creating new roles for clinical tracking of these cells. Conventional cell radiolabelling methods have been applied for some of these cell types, but for clinical use new applications will require detection of small lesions and small numbers of cells beyond the sensitivity of traditional gamma camera imaging with In-111 or Tc-99m (e.g. coronary artery disease, diabetes, neurovascular inflammation and thrombus), creating a need for positron-emitting radiolabels to exploit the better sensitivity, quantification and resolution of clinical PET.

So far the search for positron emitting (PET) radiolabels for cells has met with limited success. The near-ubiquitous presence of glucose transporters allows labelling with [18F]-FDG but labelling efficiencies are highly variable, the radiolabel is prone to rapid efflux, and the short half-life (110 min) of F-18 allows only brief tracking. Copper-64 offers a longer (12 h) half-life and efficient cell labelling using lipophilic tracers but rapid efflux of label from cells is a persistent problem and a still longer half-life would be preferred. A “PET analogue” of In-111 oxine, capable of cell tracking over 7 days or more, would be highly desirable but is not yet available.

Zr-89 Oxine: a PET cell radiolabelling agent for long term in vivo cell tracking

This paper describes the first synthesis of Zr-89 oxine, and comparison with In-111 oxine for labelling several cell lines, human leukocytes and tracking of the cancer cell line GFP-5T33 cells in mice. The new lipophilic, metastable complex of Zr-89 can radiolabel a range of cells, independently of specific phenotypes, providing a long-sought solution to the unmet need for a long half-life positron-emitting radiolabel to replace In-111 for cell migration imaging. In addition to the expected advantages (enhanced sensitivity, resolution and quantification) of cell tracking with PET rather than scintigraphy or SPECT, Zr-89 shows less efflux from cells in vitro and in vivo than In-111. GFP-5T33 is a syngeneic murine multiple myeloma model originating from the C57Bl/KaLwRij strain, engineered to express green fluorescent protein (GFP). It was chosen for this work because the fate of the cells after i.v. inoculation is known from the literature. Intravenously injected cells migrate exclusively to the liver, spleen and bone marrow. Furthermore as the radiolabelled cells were GFP positive it was possible to validate the non-invasive images by using flow sorting of the GFP positive cells and negative cells. After flow sorting the authors were able to show that after 7 days in vivo the Zr-89 Oxine cells remained viable for the duration of the study, and that ~95% of radioactivity was present in viable GFP+ cells. The excellent in vivo survival and retention of radioactivity by the cells at 7 days, coupled with the demonstrated ability to acquire useful PET images up to 14 days, significantly extend the typical period over which cells can be tracked by radionuclide imaging with directly labelled cells.

The use of PET Zr-89 oxine for cell tracking could have a dramatic impact in the investigation of infection, inflammation and cell-based therapies in humans.

Continue reading
  12292 Hits
0 Comments
12292 Hits
  0 Comments
Nov
23

Positron Emission Tomography (PET) Imaging as a treatment prediction tool for personalized nanomedicine

Positron Emission Tomography (PET) Imaging as a treatment prediction tool for personalized nanomedicine

Nanomedicine and Personalized Treatments

Nanomedicine is simply the medical application of nanotechnologies. The idea is the involvement the use of nanoparticles to improve the behaviour of drug substances. The goal is to achieve improvement over conventional chemotherapies. Customized treatments will be required to overcome the issues raised by clinical patient and disease heterogeneity. As one might expect, the same drug will accumulate in tumors at varying concentrations in patients with different cancers. But this also happens in patients with the same kind of cancer. It has to be ensured that drug nanocarriers are really accumulating in the specific tissues to better treat patients. This brings in the necessity of a treatment prediction tool to select the patients most likely to accumulate high amounts of the nanomedicine of interest and hence benefit from nanomedicinal treatment.

Positron Emission Tomography (PET) is such a noninvasive quantitative imaging tool with excellent sensitivity and spatial/temporal resolution required at the whole-body level. Radiolabeling of liposomal nanomedicines with single-photon emission computed tomography (SPECT) radionuclides has been successfully used to study their biodistribution in preclinical and clinical studies, but SPECT imaging suffers from lower sensitivity and temporal/spatial resolution than PET. However, an ideal PET radiolabeling method viable for both preclinical and clinical imaging wasn’t explored before. Rafael T. M. de Rosales, Alberto Gabizon and colleagues at King’s College London and the Shaare Zedek Medical Center sought to address this challenge.

Edmonds, S. et al. Exploiting the Metal-Chelating Properties of the Drug Cargo for In Vivo Positron Emission Tomography Imaging of Liposomal Nanomedicines. ACS Nano (2016). doi:10.1021/acsnano.6b05935

The following Mediso systems were used to conduct the animal imaging studies: nanoScan PET/CT and NanoSPECT/CT Silver upgrade. Both systems are equipped with the MultiCell animal handling and monitoring system , thus enabling a combined PET-CT/SPECT-CT imaging strategy. Interestingly both PET and SPECT were performed in the same animals (by moving the same bed from scanner from scanner, while the animals were anesthetized in fixed position) that allowed to image the tumour cells with SPECT and the nanomedicine with PET.

Liposomal Drug PET Radiolabeling Method Development

The researchers introduced a simple and efficient PET radiolabeling method exploiting the metal-chelating properties of certain drugs (e.g., bisphosphonates such as alendronate and anthracyclines such as doxorubicin) and widely used ionophores radiolabeled with long half-life metallic PET isotopes, such as 89Zr, 52Mn and 64Cu. The labels — and thus the liposomal drugs — could then be tracked using positron emission tomography (PET) to see where they go within the body. The article discusses in details the feasibility and effectiveness of their method, as well as its advantages and limitations, and show its utility for detecting and quantifying the biodistribution of a liposomal nanomedicine containing an aminobisphosphonate in vivo.

In a model of metastatic breast cancer, the researchers demonstrated that their technique allows quantification of the biodistribution of a radiolabeled stealth liposomal nanomedicine. Alendronate (ALD), an aminobisphosphonate, was selected as the radionuclide-binding drug of choice to develop this method for two reasons: (i) known ability to act as metal chelator to form inert coordination complexes with zirconium, copper, and manganese; and (ii) demonstrated anticancer activity and γ−δ T-cell immunotherapy sensitizing properties. The used liposomal formulation is referred to as PLA in the article.

Monitoring Liposomal Nanomedicine Distribution

The biodistribution of the radiolabeled liposomes was monitored using PET imaging with 89Zr-PLA in a metastatic mammary carcinoma mouse model established in immunocompromised NSG mice. This cancer model is also traceable by SPECT imaging/fluorescence due to a dual-modality reporter gene, the human sodium iodide symporter (hNIS-tagRFP), that allows sensitive detection of viable cancer tissues (primary tumor and metastases) using SPECT imaging with 99mTc-pertechnetate and fluorescence during dissection and histological studies. The imaging protocol was as follows: first, mice were injected with 89Zr-PLA (4.6 ± 0.4 MBq) at t = 0 followed by nanoScan PET-CT imaging (liposome biodistribution). The same mice were then injected with 99mTc-pertechnetate (30 MBq) and imaged by SPECT-CT. The SPECT injection was repeated at t = 24 h, 72 h, and 168 h. It was confirmed by separate phantom studies that the presence of 99mTc was not affecting the quality/quantification of the PET study. CT images revealed a significant increase in tumor volume during the imaging study. Using the tumor volumes from SPECT and CT, the researchers calculated the percentage of necrotic tumor tissue over time, by subtracting the hNIS-positive volume (SPECT) to the total tumor volume (CT). A PET-CT study was also performed using 64Cu-PLA in an ovarian cancer model (SKOV-3/SCID-Beige) over 48 h to test the versatility and capability of the radiolabeling method.

The common MultiCell animal handling and monitoring system (developed by Mediso) on both imaging systems gave the possibility to easily co-register the PET-CT/SPECT-CT and PET/SPECT studies as the animals were moved in co-registered position between the systems.

MIP video (3D, rotating along z-axis) showing co-registration of PET (red signal, 89Zr-PLA) and SPECT (green signal, 99mTcO4-, hNIS positive viable tumour tissue) of representative tumor from the mutimodal PET/SPECT study in the 3E.Δ.NT/NSG model. Both signals/radiotracers accumulate predominantly at the rim of the tumour and areas of low colocalization as well as high co-localization (yellow) are evident.

Imaging with PET in mouse models of breast and ovarian cancer showed the drugs accumulated in tumors and metastatic tissues in varying concentrations and at levels well above those in normal tissues, the researchers report. In one mouse strain, the nanomedicines unexpectedly showed up in uteruses, a result that wouldn’t have been detected without conducting the imaging study, according to the researchers.

Discussion

The results establish that preformed liposomal nanomedicines, including some currently in clinical use, can be efficiently labeled with PET radiometals and tracked in vivo by exploiting the metal affinity and high concentration of the encapsulated drugs. Importantly, the technique allows radiolabeling of preformed liposomal nanomedicines, without modification of their components and without affecting their physicochemical properties.

The versatility, efficiency, simplicity, and GMP compatibility of this method may enable submicrodosing imaging studies of liposomal nanomedicines containing chelating drugs in humans and may have clinical impact by facilitating the introduction of image-guided therapeutic strategies in current and future nanomedicine clinical studies. The ultimate goal is to use non-invasive imaging data to predict how much drug will be delivered to cancer tissues in specific patients, and whether the nanomedicine is reaching all the patient’s tumors in therapeutic concentrations.

Many thanks for Rafael T. M. de Rosales, the last author of the original article.

Continue reading
  5744 Hits
0 Comments
5744 Hits
  0 Comments
Jun
07

What is the value of “Out of date” review articles? Distortion of reality!

In the field of highly sophisticated pre-clinical imaging systems we all know that it’s important to publish articles, technical validations and independent peer reviewed performance evaluation papers on instrumentation. Eventually these performance evaluation, characterization or comparison articles make their way into review articles.

The "review article" is one of the most useful tools available for individuals who need to research a certain topic in the rapidly expanding body of scientific literature. According to Huth [1] a "well-conceived review written after careful and critical assessment of the literature is a valuable document” and it spares time for researchers to keep abreast of all published information. A review article should provide a critical appraisal of the subject.

It is extremely difficult to compare the performance of two imaging systems from different vendors if there is no standardized methodology that is independent of the camera design. Such a methodology should be applicable to a wide range of camera models and geometries. Fortunately for the Primary Investigators there is a NEMA standard publication for performance measurements of small animal positron emission tomographs (NEMA Standards Publication NU 4-2008 [2]) since 2008.

I myself have an engineering background and I’m always astonished how creatively sales people can distort the reality (i.e. numbers) in their marketing materials. I started an excel sheet back in 2007 by filling out numerous specifications for every small animal PET systems, either commercial or academic, when we started the design of our nanoScan small animal PET system at Mediso. Currently it lists about 40 pre-clinical systems including variants (while most of them are now obsolete or discontinued, such as the the Siemens Inveon). As part of my position I closely follow the published performance evaluation and review articles.

Balancing a system design is very delicate question – sensitivity and resolution do not walk hand in hand and it’s easy to get lost in the quagmire of different parameters: ultimately the detector design, the basic parameters and image characteristics together define the image quality. Also the image quality of a certain measurement series does not say anything about reproducibility, long term imaging performance, usability and feature sets.

Review of Review Article

My particular problem with instrumentation review articles is that they usually have a limited/selected subset of parameters which subconsciously (or consciously as I will give the benefit of doubt here) can lead to distortion of the reality. My apologies to the authors of the article by Kuntner & Stout, but this latest review article for preclinical PET imaging and may serve as example [3]. It is a really good article and lists various factors affecting the quantification accuracy of small PET systems. It’s a recommended article to read!

In the first table it shows the characteristics of preclinical PET scanners (visit to the link to view the original table)

The article was published on 28 February 2014, and was originally received on 27 November 2013. It references the Mediso’s microPET system based on an article from JNM 2011 [4]. However the performance evaluation of our next generation nanoScan PET was published online on August 29, 2013 in JNM [5]. Fortunately Spinks and his colleagues published a new paper on the quantitative performance of Albira PET with its largest axial FOV variant in February 2014 [6], so the Albira’s characteristics won’t be distorted – their ‘flagship’ variant is also listed. Lack of access to projection data by the researchers, the standard NEMA procedure could not be used for some of their measurements (e.g. sensitivity, scatter fraction, noise-equivalent counts).

Updated comparison table

So let’s include the updated characteristics in our new table and have a closer look on the parameters.

 

My problems with the original Table 1 in [3]:

  1. The ‘ring diameter’ was listed in the comparison table, which is quite non-relevant unless you want disassemble the system. It’s much more useful to list the bore diameter and the transaxial FOV. The bore diameter shows how wide object you can stick into the system, while the transaxial FOV shows that actually where you will collect data from!
  2. The resolution values listed are not comparable– some of them were listed according to the NEMA NU-4 2008 standard performed with SSRB+FBP (e.g. Inveon), and some of them with iterative reconstruction methods like OSEM (e.g. Genisys4). The pre-clinical PET NEMA standard allows only the usage of the filtered back projection reconstruction method to measure the resolution. More importantly the results have to show the values in all directions: in the transverse slice in radial and tangential directions and additionally the axial resolution shall be measured across transverse slices at 5, 10, 15 and 25 mm radial distances from the center. Example from [5]:

    Currently based on the published literature the nanoScan PET subsystem from Mediso delivers the best resolution values for the NEMA NU-4 2008 measurements – even without using the sophisticated 3D Tera-Tomo Reconstruction engine. Based on the original article the reader may derive the false conclusion that the Genisys4 PET delivers the best resolution – while it’s hardly the situation. The FBP recon values had not been published for Genisys4 so far.
  3. The 2D FBP recon provides comparable information on the detector design, but not the system performance! The advanced 3D iterative reconstruction methods allow to incorporate lot of corrections and they provide better spatial resolution, image characteristics – if used properly. Let’s call these resolution values performed by ‘advanced’ reconstruction methods ‘claimed by manufacturer’ values.
  4. Please always pay attention to the energy window setting when comparing sensitivity values!

Sensitivity

This is general remark for almost all review articles on preclinical PET systems with the exception of JNM article from Goertzen et al [8].

If I’d be interested in the acquisition of a capital equipment, which will be used for at least 10 years, I wanted to see not the peak sensitivity value of the system. This sensitivity is valid usually only in one position – in the radial and transaxial center of the field-of-view. In reality the standard imaged objects are mice, rats and other species, and not point- or line sources. The NEMA standard does contain a method of sensitivity measurement and evaluation for mouse and rat applications which encompass the central 7 cm and 15 cm axial extent. The problem is in practice that these parameters are not listed in the articles for most of the systems – while it’s a really useful value.

 

In the literature sensitivity values for mouse-sized region are listed only for 3 small animal PET systems: Albira, Inveon and nanoScan. For rat-sized object you can find value only for the Mediso’s system.

The Truth Lies in the Details.

References:

  1. Edward J. Huth, How to Write and Publish Papers in the Medical Sciences (Williams & Wilkins, 1990).
  2. National Electrical Manufacturers Association. NEMA Standard Publication NU 4-2008: Performance Measurements of Small Animal Positron Emission Tomographs. Rosslyn, VA: National Electrical Manufacturers Association; 2008
  3. Claudia Kuntner and David B. Stout, “Quantitative Preclinical PET Imaging: Opportunities and Challenges,” Biomedical Physics 2 (2014): 12, doi:10.3389/fphy.2014.00012. http://journal.frontiersin.org/Journal/10.3389/fphy.2014.00012/full
  4. Istvan Szanda et al., “National Electrical Manufacturers Association NU-4 Performance Evaluation of the PET Component of the NanoPET/CT Preclinical PET/CT Scanner,” Journal of Nuclear Medicine: Official Publication, Society of Nuclear Medicine 52, no. 11 (November 2011): 1741–47, doi:10.2967/jnumed.111.088260. http://jnm.snmjournals.org/content/52/11/1741.long
  5. Kálmán Nagy et al., “Performance Evaluation of the Small-Animal nanoScan PET/MRI System,” Journal of Nuclear Medicine, October 1, 2013, jnumed.112.119065, doi:10.2967/jnumed.112.119065. http://jnm.snmjournals.org/content/early/2013/08/26/jnumed.112.119065
  6. T. J. Spinks et al., “Quantitative PET and SPECT Performance Characteristics of the Albira Trimodal Pre-Clinical Tomograph,” Physics in Medicine and Biology 59, no. 3 (February 7, 2014): 715, doi:10.1088/0031-9155/59/3/715. http://iopscience.iop.org/0031-9155/59/3/715
  7. Qinan Bao et al., “Performance Evaluation of the Inveon Dedicated PET Preclinical Tomograph Based on the NEMA NU-4 Standards,” Journal of Nuclear Medicine 50, no. 3 (2009): 401–8. http://jnm.snmjournals.org/content/50/3/401.short
  8. Andrew L. Goertzen et al., “NEMA NU 4-2008 Comparison of Preclinical PET Imaging Systems,” Journal of Nuclear Medicine 53, no. 8 (2012): 1300–1309. http://jnm.snmjournals.org/content/53/8/1300.short
  9. Stephen Adler, Jurgen Seidel, and Peter Choyke, “NEMA and Non-NEMA Performance Evaluation of the Bioscan BioPET/CT Pre-Clinical Small Animal Scanner,” Society of Nuclear Medicine Annual Meeting Abstracts 53, no. Supplement 1 (May 1, 2012): 2402. http://jnumedmtg.snmjournals.org/cgi/content/meeting_abstract/53/1_MeetingAbstracts/2402
  10. Ken Herrmann et al., “Evaluation of the Genisys4, a Bench-Top Preclinical PET Scanner,” Journal of Nuclear Medicine, July 1, 2013, doi:10.2967/jnumed.112.114926. http://jnm.snmjournals.org/content/early/2013/04/29/jnumed.112.114926
  11. F. Sánchez et al., “Small Animal PET Scanner Based on Monolithic LYSO Crystals: Performance Evaluation,” Medical Physics 39, no. 2 (2012): 643, doi:10.1118/1.3673771. http://link.aip.org/link/MPHYA6/v39/i2/p643/s1&Agg=doi
Continue reading
  20410 Hits
0 Comments
20410 Hits
  0 Comments
Apr
28

BSL-3 compatible small animal molecular imaging chamber for tuberculosis research

Introduction:

Small Animal Molecular imaging of infectious diseases in lung is becoming more and more important, especially at the time of COVID-19 outbreak. Dr. Sanjay K. Jain and his research group in Center for Infection and Inflammation Imaging Research (Ci3R, John Hopkins University) focuses on studying the pathogenesis of bacterial diseases, with a major focus on tuberculosis (TB). They have developed a pipeline of bacteria-specific PET-based imaging tracers. They also have developed imaging techniques to noninvasively determine antimicrobial penetration into infected lesions and understand lesions-specific host-responses. They translate their preclinical findings to the clinic and are testing some novel imaging tracers developed in their laboratory in human studies. For pre-clinical molecular imaging technique they are using Mediso nanoScan PET/CT, so they are able to follow kinetic changes of a drug distribution in high temporal resolution, and can locate sites of pathogen and inflammation in high spatial resolution.

The main challenge working with M. tuberculosis, and working with SARS-CoV-2 even, is that it requires Biosafety Level 3 (BSL-3) environment. Dr. Jain and his co-workers have developed sealed biocontainment chambers for mouse and rabbit compliant with BSL-3 requirements in house. The high versatility and open design of nanoScan PET/CT allowed them to install their chamber on the Mediso system. Working in a BSL-2 environment with a BSL-3 compatible chamber makes researcher’s life easier. For these reasons Mediso in collaboration with Dr. Jain has developed a commercially available BSL-3 compatible chamber for the PET/CT MultiCell™ imaging system, (see details below).

Clinical study findings supported by small animal imaging on Mediso nanoScan PET/CT

Ordonez et al. “Dynamic Imaging in Patients with Tuberculosis Reveals Heterogeneous Drug Exposures in Pulmonary Lesions.” Nature Medicine 26, no. 4 (April 2020): 529–34. (https://doi.org/10.1038/s41591-020-0770-2)

In this recent publication Ordonez et al. provided estimates on rifampin dosing, a first-line TB drug, required to achieve faster cure in 4 months. Newly identified patients were enrolled in a first-in-human study using dynamic [11C]rifampin positron emission tomography (PET) and computed tomography (CT). The findings from human studies were supported with small animal imaging using Mediso nanoScan PET/CT (extended data in publication Fig. 6). 

An interesting finding was that [11C]rifampin exposures in human pulmonary TB lesions were low, were spatially compartmentalized and demonstrated between-patient and within-patient variability. [11C]rifampin (tissue-to-plasma) AUC ratios demonstrate limited [11C]rifampin exposure in lesions, with the lowest exposure noted in cavity walls, which paradoxically also have the highest bacterial burden. The pharmacokinetic studies conducted on a rabbit model also demonstrated limited and spatially compartmentalized [11C]rifampin exposures in TB lesions, with the lowest exposures in cavity walls.

The authors hypothesize that tissue necrosis and presumably the fibrotic extracellular matrix surrounding cavitary tissues limited the ability for passive diffusion and rifampin penetration into these lesions, thus minimizing the spread.

Commercially available BSL-3 compliant imaging chamber from Mediso

Mediso has developed in collaboration with Dr. Sanjay K. Jain a commercially available BSL-3 compliant imaging chamber for MultiCell™ imaging system.

The advance of using this chamber is that the PET/CT scanner doesn’t have to be in BSL-3 laboratory, so the animal imaging and the scanner maintenance become much easier. Moreover, the scanner in a such setup can be used for non BSL-3 required animal studies also.

As a workflow, the animals are anesthetized in a BSL-3 environment and placed into the imaging chamber and then sealed. The outer surface of the chamber is decontaminated before caring to BSL-2 environment.

The chamber can be attached by one-click to the scanner’s docking stage without any further tube connection. The anesthesia gas flows in and out through a 0.3 um pore filter. The heating air is circulating only in the chamber’s wall, so there is no transit between the heating air compartment and the chamber space. For kinetic studies the animal is cannulated in BSL-3 and the tubing is led out through a sealed opening (see Figure 1.)

This practical solution provides a tenable and flexible mechanism for routine imaging and for implementing the more severe constraints necessitated by BSL-3 imaging procedures in a simple and expeditious manner.

Figure 1. MultiCell™ BSL-3 compliant imaging chamber

Continue reading
  1385 Hits
0 Comments
1385 Hits
  0 Comments